IKI-35_24V

IKI-35_24V

Self powered protection relay acc. IEC 60255 Applicable for transformers with nominal... more
Product information "IKI-35_24V"

Self powered protection relay acc. IEC 60255

  • Applicable for transformers with nominal power between 160 and 12 500 kVA; as overcurrent, short-circuit or earth-fault Protection Relay in combination with a Circuit Breaker and as overcurrent protection in combination with Load Breakers and High Voltage Fuses

Software based parameterization via USB with Windows software Kries-Config

Selectable tripping options

  • IDMT stage (ANSI 51)
  • DMT stage (ANSI 51) (four characteristics)
  • Two instantaneous overcurrent characteristic (ANSI 50)
  • External fast tripping without delay
  • Optional earth fault protection (ANSI 51N)

Release of tripping coil

  • Low-power coil (no external supply needed)
  • Standard tripping coil (with seperate power storage PSU unit )

Self test

  • On site test of function by test button
  • Dry contact for remote transmission of watchdog alarm

Free of maintenance, CT-powered

  • Power supply buffered by lithium battery (life cycle -> 15 years)

Stromwandler

Weitbereichswandler               

Typ IKI-LUM

Nennstrom

IN

einstellbar 10 ... 250 A (Standard)

   

einstellbar 100 ... 400 A (mit HC-Adapter)

Kurzschlussstufe I>>:

   

Ansprechwerte

Verhältnis I>>>/In, I>>/In

einstellbar 2 ... 20 oder deaktiviert

Verzögerungszeit

tI>>>, tI>>

einstellbar 0 ... 2 s

Überstromstufe I>:

   

UMZ Ansprechwert

Verhältnis I>/ In einstellbar 1,1 ... 3

Verzögerungszeit

tI> einstellbar 0,3 ... 300 s

AMZ 1/2/3/4

inverse Charakteristik einstellbar 1. extremely; 2. very; 3. normal; 4. long time

Startwert

Verhältnis I>/In einstellbar 1,1 ... 3

Verschiebungsfaktor

 v einstellbar 0,05 ... 10 s

Erdschlussstufe Ie>:                 

    

 

Ansprechwert Ie>>

Verhältnis Ie>>/In

einstellbar 0,1 ... 2 oder deaktiviert

Verzögerungszeit

tIe>>

einstellbar 0 ... 2 s

Ansprechwert UMZ Ie>

Verhältnis Ie>/In

einstellbar 0,1 ... 2

Verzögerungszeit

tIe>

einstellbar 0 ... 5 s

AMZ 1/2/3/4 Ie>

inverse Charakteristik

einstellbar 1. extremely; 2. very; 3. normal; 4. long time

Startwert

Verhältnis Ie>/In

einstellbar 0,1 ... 2

Verschiebungsfaktor

v

einstellbar 0,05 ... 10 s

Frequenz       

f                               

 einstellbar 50/60 Hz

Eigenzeit

   ca. 43 ms

Reset

 der Anzeige „Auslösung“  einstellbar 2h/4h/8h, autom. nach Stromwiederkehr, manuell

Relais

 2  einstellbar: NC/ NO., einstellbare Logik: I> + Ie>; I>; Ie>; Trip

Versorgung

wandlerversorgt     

 gepuffert durch Lithiumbatterie, optional Hilfsenergie 24..230 VAC/DC

Summensignal I0

über Asymmetrieberechnung der drei Leiterumbauwandler oder mit optionalem Summenwandler am Eingang 4

 

Produktnorm

IEC 60255-5

 

Betriebs- und Lagertemperatur

-40 °C ... +70 °C / -40 °C ... +80 °C

 

Gehäuse

 

 

 

Fronttafeleinbau                      

Abmessungen                         

empfohlener Ausschnitt                                               

 DIN 43700

b x h x t = 96 x 48 x 80 mm

92 x 45 mmIP 40   

Schutzgrad

IP 40

Optional Schutzgrad Front: IP 54

Stromwandler

Eingänge 1, 2, 3:

Leiterumbauwandler Typ IKI-LUM-D92

 

optional für Eingang 4:

Summenumbauwandler Typ IKI-GSU_d60_314_diwi