This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Track device being used
CAPDIS-Sense
Voltage sensor for retrofitting, 1-24 kV, for non-controlled end closures, for air-insulated switchgears
Item number: 2500409_H001
Item number: 2500409_H001
CAPDIS-Sense is used to retrofit a capacitive tap in air-insulated switchgears without having to... more
Product information "CAPDIS-Sense"
CAPDIS-Sense is used to retrofit a capacitive tap in air-insulated switchgears without having to intervene in the switchgear. The capacitive tap enables voltage testing via the integrated Voltage Detecting Systems VDIS of the CAPDIS series, as well as further fault direction detection with fault direction indicators of the IKI series.
Wide voltage range
Applicable at 6 ... 24 kVSensor for fault direction detection
In conjunction with fault direction detection devices of the IKI series and a CAPDIS, the sensor can be used for easy retrofitting of air-insulated systems.Easy retrofit
The sensor can be installed in the switchgear without any structural intervention.Increase personal safety
No longer necessary to perform the voltage absence test with open doors of air-insulated switchgears. With retrofitting of the sensor and a CAPDIS, the switchgear door remains closed during voltage absence testing. This increases the personal safety of the operating personnel.Device data | |
Article number | 2500409_H001 |
Product designation | Capacitive voltage sensor | Retrofit | Air-insulated switchgears |
Dimensions | |
Mounting | Screw connection for shield connection of the coaxial cable |
Operating conditions | |
Operating temperature | -25°C ... 55°C |
Storage temperature | -30°C ... 75°C |
Protection class | IP41 |
Applicable at nominal frequency | 50 Hz, 60 Hz |
Inner diameter | 52 mm |
Rated voltage | 24 kV |
Coupling capacitance C1 | 2 pF |
Mounting | Screw connection for shield connection of the coaxial cable |
Coaxial cable set
For CAPDIS and capacitive sensors, with AK-Socket für adapter cable AK, RG58, 3 m, without broken lead detection
Price on request