This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Google Analytics
Track device being used

IKI-50_1F_PULS_EW_104
Universal Feeder Control Units, IEC-104, single-field monitoring, pulsation, wiper mode
Item number: 2500530_H001
Item number: 2500530_H001
The universal Feeder Control Unit IKI-50_104 is the appropriate solution for intelligent... more
Product information "IKI-50_1F_PULS_EW_104"
The universal Feeder Control Unit IKI-50_104 is the appropriate solution for intelligent distribution network stations and offers distribution network operators a high degree of transparency and cost-effectiveness. The IKI-50_104 includes all algorithms for selective fault detection. It is suitable for all neutral point treatments. Switching commands for load switch control can be fed to the IKI-50_104 via communication bus and executed field-related with 1.5-pole switching safety. The IKI-50_104 has an interface with IEC 60870-5-104 protocol, as well as a ModbusRTU master function for querying underlying measuring devices such as IKI-50.
Load flow measurement
- Voltages, currents, powers, frequencies, cos-phi ...
- Momentary and average values
- Limit monitoring
Fault detection
- directional short-circuit detection
- directional earth fault detection, directional static earth fault detection (wattmetric method), directional transient earth fault detection (wiper method), earth fault detection via pulse locating
- early fault detection via detection of transient faults
- suitable for all neutral point treatments
- no summing transformer required
Network automation
- extensive logic functions freely programmable with PC- Software KriesConfig
Maintenance-free
- no battery
- unlimited data retention
- error indication in case of power failure over 6 hours
IEC 60870-5-104
- The device has a network connection for direct communication with control centers or telecontrol via IEC-104 protocol.
Webserver
- Configuration of the parameters for the IEC-104 connection via integrated webserver
ModbusRTU master function
- Modbus slave devices (e.g. IKl-50 in the standard version) can additionally be queried via the IKl-50_ 104. The conversion to IEC-104 is then also done in the device.
Security
- Password protected configuration
- Access rights management- Web server can be switched off- Encryption of the connection via VPN router possible
Device data | |
Article number | 2500530_H001 |
Product designation | IKI-50_1F_PULS_EW_104Universal Feeder Control Units | IEC-104 | single-field monitoring | pulsation mode | wiper mode |
Operating elements and display | |
Direction keys | Operation via four direction keys |
Two feeder monitoring | ✘ |
Dimensions and installation instructions | |
Case height x width x depth | 49 x 96 x 108 mm |
Cutout height x width | 45 x 92 mm |
Norm cutout dimensions | DIN IEC 61554:2002-08 |
Installation type | Panel mounting |
Sheet thickness | 1.5 ... 2.5 mm |
Operating conditions | |
Operating temperature | -25°C ... 55°C |
Storage temperature | -25°C ... 70°C |
Humidity | max. 95 % relative Feuchte bei 40° C |
Protection class | IP54 (Front) |
Fault detection and failure forecast | |
Directional short-circuit detection I>> | ✓ |
Threshold current short-circuit detection I>> [A] | 100, 200, 300, 400, 600, 800, 1000 |
Automatic response threshold Short circuit detection | ✘ |
Threshold time short-circuit detection I>> [ms] | 40, 60, 80, 100, 150, 200, 400, 1200, 1600 |
Directional earth short-circuit detection Ie>> | ✓ |
Earth fault transient detection | ✓ |
Interfaces and communication | |
USB interface | Mini-USB |
Modbus RTU Master | ✓ |
Modbus-RTU Slave | ✘ |
IEC 60870-5-104 Slave | ✓ |
Slave test | ✘ |
Digital Inputs | 4 |
Connection cable cross section | Max. 2,5 mm |
Switching capacity relay | AC: max. 62,5 VA max. 2A; max. 250 VAC DC: max. 2A @ 40 VDC |
Measurement values and functions | |
Voltage measurement | ✓ |
Measuring range voltage | Capacitive |
Phase-to-ground voltages | ✓ |
Phase to phase voltages | ✓ |
Measuring range voltage | 0.02 kV ... 92 kV | Start of voltage measuring range: 2% of Un |
Accuracy voltage measurement | 3 % of measurement value |
Current measurement | ✓ |
Measuring range current | 0.5 A ... 1,158 A (with current transformer IKI-LUM) |
Zero-sequence current | ✓ |
Accuracy current measurement | 3 % of measurement value |
Conductor currents | ✓ |
Active power | ✓ |
Reactive power | ✓ |
Apparent power | ✓ |
Rotary field detection | ✓ |
Frequency measurement | ✓ |
Mean value determination | ✓ |
Min-max value determination | ✓ |
Phase position | ✓ |
Phase shift cos-phi | ✓ |
Limit value monitoring | Voltage, current, frequency, reactive power and voltage |
Logic functions | A total of 32 logic rules can be programmed. |
Power supply | |
Auxiliary power supply | 24...230 VAC/DC (jeweils 15 %) |
Power consumption | 2 W |
Insulation voltage | 2 kV, 1 min |