This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Track device being used
CAPDIS-S2_HV (R5)
Capacitive Voltage Detecting Systems with Relay Contacts, with Partial Discharge Detection, for High Voltage
Item number: 2502134_H009
Item number: 2502134_H009
The CAPDIS-S2_HV (R5) is an integrated Voltage Detecting Systems for checking for absence of... more
Product information "CAPDIS-S2_HV (R5)"
The CAPDIS-S2_HV (R5) is an integrated Voltage Detecting Systems for checking for absence of voltage in high-voltage switchgear in accordance with IEC 62271-213:2021 (or IEC 61243-5) with integrated three-phase continuous indication and Signaling outputs. It also allows detection of partial discharges in the station and its surroundings.
Voltage Detecting Systems VDIS for High Voltage (52 - 480 kV)
Testing for absence of voltage in high voltage switchgear according to IEC 61243-5 resp. IEC 62271-213 with integrated three-phase continuous display.Partial discharge detection
Critical partial discharge levels are detected, shown on the display and output via the relay collective fault signal. The sensitivity of the PD detection is set or also deactivated via a DIP switch on the rear of the device. A socket behind the front flap is available for PD diagnostics.Maintenance-free due to self-monitoring, fail-safe
No periodic retesting according to IEC 61243-5 or IEC 62271-213 u. BGV A3 required, as the device permanently monitors the response threshold and displays it with a three-stage voltage level indicator (half, full and outlined lightning arrow).Integrated self-test function
No external test device is required to test for absence of voltage. Integrated function test by means of test button, according to patent DE 103 04 396. Clear indication of primary voltage present and not present.Relay outputs and LED displays
For remote monitoring of voltage states, two signal relays [changeover contacts] are integrated, which are operated with auxiliary voltage. The status of the relays is additionally indicated via LEDs in the front.Integrated V-interface
For further processing of the voltage signals via a smart grid system (e.g. IKI-50, IKI-22) connection via optional Y-cable.Integrated three-phase measuring point
The device has a three-phase LRM measuring point for phase comparison, rotating field direction measurement e.g. by means of CAP phase or connection of CAPDIS-M.No battery required
Voltage test as well as self-test without battery or auxiliary voltage.Device data | |
Article number | 2502134_H009 |
Product designation | CAPDIS-S2_HV (R5) Capacitive Voltage Detecting Systems with relay contacts | with partial discharge detection| for high voltage |
Standard | IEC 61243-5, IEC 62271-213 |
Required data for order | Rated operating voltage Un, coupling capacitance C1 |
Functions | |
Intrinsic safety | Device is intrinsically safe |
Maintenance test | No periodic inspections are necessary for this device |
Broken lead detection | Can be activated/deactivated via DIP switches |
Partial discharge detection |
|
Controls and display | |
Response time relay | <= 0,2 s |
Front display | Monochrome LC display and colored LEDs |
Controls | Self-test button |
Dimensions and type of installation | |
Case height x width x depth | 48 x 96 x 37 mm |
Cutout height x width | 45 x 92 mm |
Norm cutout dimensions | DIN IEC 61554:2002-08 |
Installation type | Panel mounting |
Operating conditions | |
Operating temperature | -25°C ... 55°C |
Storage temperature | -30°C ... 75°C |
Protection class | IP54 |
Voltage level | 53..480 kV (High-voltage) |
Rated frequency | 50 Hz, 60 Hz |
Type of interface | LRM |
Lifetime | Minimum 22 years (MTBF) |
Signaling outputs | |
Connection of connecting cables | By means of flat plug sleeve 4.8 x 0.8 mm or system plug (order separately) |
Switching capacity relay | 250 VAC, 5 A (resistive load) / 30 VDC, 5 A / 250 VDC 0.3 A (resistive load) |
Voltage supply | |
Auxiliary power supply | 24 - 230 V AC/DC +-10% |
Power supply | 24 - 230 V AC/DC +- 10%; Power input < 1 Watt |
Power consumption | < 1 W |
Insulation voltage | 2 kV |