This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Track device being used
IKI Primary test with cable and carrying case
Primary Tester for Fault Indicators of IKI-Line
Item number: 2510094
Item number: 2510094
Primary test instrument for all non-directional and directional fault indicators as well as field... more
Product information "IKI Primary test with cable and carrying case"
Primary test instrument for all non-directional and directional fault indicators as well as field control units of the IKI-Line.
Due to the primary test mode of the fault indicator or field control unit, a minimum primary current of 3 A is sufficient for testing. If this is not available because the medium voltage has not yet been connected, a test current of 5 A can be generated with the IKI primary test and passed through the current transformers with the thin test cable. The IKI units detect the current and signal it accordingly, depending on the unit version (LCD, LED, relay). This checks the complete measuring circuit of the fault indicator.
For directional fault indicators, the load flow direction can also be checked with the voltage output.
Testing of the earth fault detection function pulsation possible.
The transformer does not have to be opened for looping through the test cable.
Complete operation via three control buttons.
Suitable for all fault indicators and field control units of the IKl-Line
Due to the primary test mode of the fault indicator or field control unit, a minimum primary current of 3 A is sufficient for testing. If this is not available because the medium voltage has not yet been connected, a test current of 5 A can be generated with the IKI primary test and passed through the current transformers with the thin test cable. The IKI units detect the current and signal it accordingly, depending on the unit version (LCD, LED, relay). This checks the complete measuring circuit of the fault indicator.
Checking the load flow direction
For directional fault indicators, the load flow direction can also be checked with the voltage output.
Integrated test module pulsation
Testing of the earth fault detection function pulsation possible.
Reduced test time due to simple wiring
The transformer does not have to be opened for looping through the test cable.
Simplest testing
Complete operation via three control buttons.
Handy device in transport case
General data | |
Article number | 2510094 |
Quantity unit | Piece |
Product designation | IKI Primary test with cable and carrying case |
Operating conditions | |
Operating temperature | -25°C ... 50°C |
Protection class | IP65 |
Power supply | 230 VAC |