This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Track device being used
IKI-22_PF
Directional short-circuit and earth fault indicator, monostable wiper contacts
Item number: 2501991_H001
Variants Item number: 2501991_H001
The IKI-22 is a combined short-circuit and earth fault indicator with direction detection. It can... more
Product information "IKI-22_PF"
The IKI-22 is a combined short-circuit and earth fault indicator with direction detection. It can be operated both with and without auxiliary power and is suitable for all neutral earthings.
Variant with wiper contacts as alarm outputs.
Variant with wiper contacts as alarm outputs.
Directional fault detection for all network types
Directional detection, indication and remote signalling of short circuits and earth faults. In compensated and isolated networks the directional earth fault is detected with the transient earth fault wiper method.Voltage information from the Capdis voltage detecting system
The voltage signals required for directional detection are obtained from the CAPDIS® or CAPDIS-PI voltage detecting system by means of a Y-cable.Earth fault detection without balanced core CT
The summation signal is calculated from the three phase current sensors. A balanced core CT is not required, thus minimizing the installation effort.Operation without auxiliary power possible
Short-circuit and earth fault detection in networks with grounded neutrals are possible without connecting auxiliary power. For directional detection of earth faults in compensated and isolated networks with the transient earth fault wiper principle, an unprotected auxiliary voltage is required.Simple operation and adjustment
Operation and display of the device are designed according to the IKl-20 family: The LCD display shows the fault type phase-selectively. For recloser applications, there is a differentiated display of the first and second fault. Two separate LEDs indicate the error direction. The parameterization is done via DIP switches behind the front cover. The test/reset button is used to test the function and to reset an error indication.Alarm contacts
The contacts are potential-free and designed as monostable wiper contacts.Device Data | |
Article number | 2501991_H001 |
Quantity unit | Piece |
Product designation | IKI-22_PF Directional short-circuit and earth fault indicator | monostable contact |
Controls and display | |
Front display | LC-Display and LEDs |
Test button | ✓ |
Red LED (1) | Error in direction of cable |
Yellow LED (2) | Fehler in Richtung Sammelschiene |
Buffer of power supply | Battery |
Dimensions and installation | |
Case height x width x depth | 48 x 96 x 80 mm |
Cutout height x width | 45 x 92 mm |
Norm cutout dimensions | DIN IEC 61554:2002-08 |
Installation type | Panel mounting |
Sheet thickness | 1.5 ... 2.5 mm |
Climatic conditions | |
Operating temperature | -25°C ... 55°C |
Storage temperature | -25°C ... 70°C |
Humidity | max. 95 % relative humidity at 40° C |
Protection class | IP40 |
Fault detection | |
Star point types | Isolated neutral, Short-term low-ohmic terminated neutral, Low-ohmic terminated neutral, Inductive terminated neutral |
Short circuit detection I>> | ✓ |
Directional short-circuit detection I>> | ✓ |
Threshold current short-circuit detection I>> [A] | 100, 200, 300, 400, 600, 800, 1000, 2000 |
Automatic response threshold Short circuit detection | - |
Threshold time short-circuit detection I>> [ms] | 40, 80, 150, 200 |
Earth short-circuit detection Ie>> | ✓ |
Directional earth short-circuit detection Ie>> | ✓ |
Threshold current earth short-circuit detection Ie>> [A] | 40, 80, 100, 200 |
Threshold time earth short-circuit detection Ie>> [ms] | 60, 80, 150, 200 |
Directional static earth fault detection Ie>; | - |
Directional transient earth fault detection Ie> | ✓ |
Threshold current transient earth fault detection 3I0 [A] | 100, 200, 300, 500 |
Threshold voltage transient earth fault detection 3U0 [%] | 20, 50 |
Earth fault detection via pulse locating | - |
Transient fault detection IIe> | - |
Step voltage monitoring | - |
Fault reset | Auto, After 2h, 4h, Manually on the device, External potential-free normally open contact |
Earth fault transient detection | ✓ |
Directional earth short-circuit detection | ✓ |
Communication | |
DIP switch for parameterization | ✓ |
Modbus-RTU | - |
Slave test | ✓ |
Digital Inputs | 1 |
Remote signalling | 4 contacts Monostable Ron = 35 Ohm |
Remote test | Function test including switching of the remote signalling contacts possible by connecting a potential-free normally open contact to the slave input. |
Switching capacity relay | Umax 110 V AC/DC, Imax 100 mA |
Voltage inputs | 1 |
Measurement values and functions | |
Voltage measurement | - |
Cross calibration | - |
Current measurement | - |
Measuring range current | 35..2.000 A (short-term) |
Rotary field detection | ✓ |
Auxiliary power | |
Auxiliary power supply | 24 … 230 V AC/DC (jeweils 15 %), needed for earth fault detection with transient algorythm |
Power consumption | 1 W |
Insulation voltage | 1 kV; 1 min |
Battery type | Lithium |
CT-supplied | ✓ |
Notes on transformer supply | From 15 A three-phase |
IKI-LUM d92
CT for bushings, directional, for measured value acquisition, for C-cone, set
Price on request
IKI-LUM d92
CT for bushings, directional, for measured value acquisition, for Siemens switchgears, set
Price on request